Model |
SUN-3.6K-G04 |
SUN-4K-G04 |
SUN-4.2K-G04 |
SUN-4.6K-G04 |
SUN-5K-G04 |
SUN-5.2K-G04 |
SUN-6K-G04 |
SUN-6.2K-G04 |
PV String Input Data |
Max. PV Input Power (kW)
|
4.7 |
5.2 |
5.46 |
5.98 |
6.5 |
6.76 |
7.8 |
8.06 |
Max. PV Input Voltage (V) |
550 |
Start-up Voltage (V) |
80 |
MPPT Voltage Range (V) |
70-500 |
Rated PV Input Voltage (V) |
360 |
Max. Operating PV Input Current (A) |
13+13 |
Max. Input Short Circuit Current (A) |
19.5+19.5 |
No. of MPP Trackers/No. of Strings
per MPP Tracker
|
2/1+1 |
AC Output Side |
Rated AC Output Active Power (kW) |
3.6 |
4 |
4.2 |
4.6 |
5 |
5.2 |
6 |
6.2 |
Max. AC Output Apparent Power (kVA) |
3.96 |
4.4 |
4.62 |
5.06 |
5.5 |
5.27 |
6.6 |
6.82 |
Rated AC Output Current (A) |
16,4/15,7 |
18,2/17,4 |
19.1/18.3 |
20.9/20 |
22,7/21,7 |
23,7/22,7 |
27,3/26,1 |
28.2/27 |
Max. AC Output Current (A) |
18/17.2 |
20/19.1 |
21/20.1 |
23/22 |
25/23.9 |
26/24.9 |
30/28,7 |
31/29.7 |
Rated Output Voltage/Range (V) |
220/230 0,85Un-1,1Un |
Grid Connection Form |
L/N/PE |
Rated Output Grid Frequency/Range(Hz)
|
50/45-55, 60/55-65 |
Power Factor Adjustment Range |
0.8 leading to 0.8 lagging |
Total Current Harmonic Distortion THDi |
<3% |
DC Injection Current |
<0.5%ln |
Efficiency |
Max. Efficiency |
97,30% |
97,50% |
Euro Efficiency |
96,90% |
97,00% |
MPPT Efficiency |
>99% |
Equipment Protection |
DC Polarity Reverse Connection
Protection
|
Yes |
AC Output Overcurrent Protection |
Yes |
AC Output Overvoltage Protection |
Yes |
AC Output Short Circuit Protection |
Yes |
Thermal Protection |
Yes |
DC Terminal Insulation Impedance
Monitoring
|
Yes |
DC Component Monitoring |
Yes |
Ground Fault Current Monitoring |
Yes |
Disyuntor de falla de arco (AFCI)
|
Optional
|
Power Network Monitoring |
Yes |
Island Protection Monitoring |
Yes |
Earth Fault Detection |
Yes |
Overvoltage Load Drop Protection |
Yes |
Residual Current (RCD) Detection |
Yes |
Surge Protection Leve |
TYPE II(DC), TYPE II(AC) |
Interface |
Communication Interface |
RS485/RS232 |
Monitor Mode |
GPRS/WIFI/Bluetooth/4G/LAN (opcional)
|
General Data |
Operating Temperature Range (°C) |
-25 to +65℃, >45℃ Derating |
Permissible Ambient Humidity |
0-100% |
Permissible Altitude (m) |
2000m |
Noise (dB) |
≤35 |
Ingress Protection(IP) Rating |
IP 65 |
Inverter Topology |
Non-Isolated |
Over Voltage Category |
OVC II(DC), OVC III(AC) |
Cabinet Size (WxHxD mm |
330×323×190 (Excluding Connectors and Brackets) |
Weight (kg) |
8 |
Warranty |
5 Years |
Type of Cooling |
Natural Cooling |
Grid Regulation |
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G99, VDE-AR-N 4105 |
Safety EMC/Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |